Conductor
Material
Oxygen-free copper (99.97%)
Diameter
0.81 mm±0.1 mm (0.03″±0.004″)
Wire Gauge
20AWG
Insulation
Material
FPE
Thickness
≥1.4 mm (0.06″)
Diameter
3.7 mm±0.20 mm (0.15″±0.008″)
Color
White
Inner Shield
Material
Aluminum foil
Specification
T≥0.026, W: 15±1 mm (0.59″±0.04″)
Overlap Rate
≥25%
Outer Shield
Material
Copper clad aluminum
Specification
16 × 4 × 0.12 mm±0.01 mm (0.005″±0.0004″)
Shield Coverage
≥60%
Sheath
Material
PVC
Thickness
≥0.95 mm (0.04″)
Diameter
6.1 mm±0.30 mm (0.24″±0.01″)
Color
Black semi-polished
Electrical
Max. DC Resistance of Inner Conductor
≤33.9Ω/km
Dielectric Strength
Not breakdown with 2kV DC for 1 min
Sheath Strength
Not breakdown with 3kV
Characteristic Resistance
75Ω±5Ω
Insulation Resistance
5000MΩ•km
Mechanical
Elongation at Break (Wire)
≥15%
Elongation at Break (Sheath)
≥150%
Environment
Low-Temperature Bending
Not cracked
Thermal Shock
Not cracked
Operating Temperature
–20°C to +60°C (–4°F to 140°F)
Storage Temperature
–10°C to +40°C (14°F to 104°F)
Package
Length
200 m±1.5 m (656 ft±4.92 ft)
Packaging Dimensions
332 mm × 144 mm × 341 mm (13.07″ × 5.67″ × 13.43″) (L × W × H)
Net Weight
7.3 kg±0.5 kg (16.09 lb±1.10 lb)
Gross Weight
7.9 kg±0.5 kg (17.42 lb±1.10 lb)
Certification
Certification
CPR Eca
Executive Standard
Q/DXJ 194-2020
Coaxial Cable Transmission Performance
Frequency (MHz)